• Users Online: 508
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
RESEARCH ARTICLE
Year : 2022  |  Volume : 59  |  Issue : 1  |  Page : 57-62

Validation of micro-chip based PCR assays for diagnosis of both Plasmodium falciparum and Plasmodium vivax


1 ICMR-National Institute of Malaria Research, New Delhi, India
2 Indian Council of Medical Research, New Delhi, India

Correspondence Address:
Ramesh C Dhiman
ICMR-National Institute of Malaria Research, Sector-8, Dwarka, New Delhi 110077
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-9062.328978

Rights and Permissions

Background & objectives: Microscopy is considered as the gold standard for malaria diagnosis, however sub-microscopic infections can only be detected by Polymerase chain reaction, which demands high cost and elaborate laboratory setup. The Micro-chip PCR based Truenat Malaria Pv-Pf and Pf assay is a portable solution for detection of sub-microscopic/asymptomatic cases of malaria in the field, three lots of which were evaluated for P. falciparum and P. vivax malaria. Methods: Three lots of Truenat® Malaria Pv-Pf and Pf assay (kits) were assessed using blood samples of P. vivax and P. falciparum as well as malaria negative blood samples. DNA was extracted from the blood samples using the Trueprep Auto v2 Universal Cartridge based sample prep device and real time qPCR was performed using Truelab DUO micro PCR Analyzer with three lots of Truenat® Malaria Pv-Pf and Pf Assays. Mean, Standard deviation and one-way analysis of variance (ANOVA) was used to assess the significance of inter-lot variability in Cycle threshold values. Results: The Truenat® Malaria Pv-Pf and Pf assays identified the malaria parasites with 100% accuracy. Based on the test for variance (ANOVA) the inter-lot variability in cycle threshold values were not significant, indicating a high degree of precision. Interpretation & conclusion: Based on high accuracy and precision between different lots, the Truenat® Malaria Pv-Pf and Pf assays were found to be suitable for the diagnosis of sub-microscopic infections in field conditions to provide support in elimination of malaria.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed908    
    Printed2    
    Emailed0    
    PDF Downloaded35    
    Comments [Add]    

Recommend this journal